National Repository of Grey Literature 4 records found  Search took 0.00 seconds. 
Testing of an Accuracy of Mobile Laser Scanning
Hoffmannová, Lada ; Volařík, Tomáš (referee) ; Kuruc, Michal (advisor)
Diploma thesis describes collecting of data by mobile mapping system Riegl VMX-450. Science centre AdMas was captured with mobile mapping system. For the purpose of testing the accuracy, a calibration field was constructed in AdMaS. Main part of the thesis deals with testing of the accuracy of point cloud. Calibration field's coordinates were obtained by adjustment of the geodetic network using the least squares adjustment. During the testing, the coordinates of the calibration field points determined by the adjustment of the geodetic network and the coordinates of the points determined from the point cloud were compared. Another part of the work deals with testing of the accuracy, when target's position is in different height levels.
Accuracy testing of mobile photogrammetry
Otrusinová, Jana ; Hanzl, Vlastimil (referee) ; Kalvoda, Petr (advisor)
This diploma thesis deals with a construction of a calibration field in the area of the AdMaS research centre (Brno University of Technology). Furthermore, photogrammetric data from the Riegl VMX-450 mobile mapping system has been acquired and processed. Selected points of the calibration field were used as control points. The other points of the calibration field were used as check points. As part of the testing, the coordinate deviations at the check points were assessed. The difference between the accuracy of mobile laser scanning and mobile photogrammetry was also evaluated. Coordinate deviations of mobile photogrammetry were tested according to standard ČSN 01 3410. Furthermore, a point cloud and a textured 3D model were generated.
Accuracy testing of mobile photogrammetry
Otrusinová, Jana ; Hanzl, Vlastimil (referee) ; Kalvoda, Petr (advisor)
This diploma thesis deals with a construction of a calibration field in the area of the AdMaS research centre (Brno University of Technology). Furthermore, photogrammetric data from the Riegl VMX-450 mobile mapping system has been acquired and processed. Selected points of the calibration field were used as control points. The other points of the calibration field were used as check points. As part of the testing, the coordinate deviations at the check points were assessed. The difference between the accuracy of mobile laser scanning and mobile photogrammetry was also evaluated. Coordinate deviations of mobile photogrammetry were tested according to standard ČSN 01 3410. Furthermore, a point cloud and a textured 3D model were generated.
Testing of an Accuracy of Mobile Laser Scanning
Hoffmannová, Lada ; Volařík, Tomáš (referee) ; Kuruc, Michal (advisor)
Diploma thesis describes collecting of data by mobile mapping system Riegl VMX-450. Science centre AdMas was captured with mobile mapping system. For the purpose of testing the accuracy, a calibration field was constructed in AdMaS. Main part of the thesis deals with testing of the accuracy of point cloud. Calibration field's coordinates were obtained by adjustment of the geodetic network using the least squares adjustment. During the testing, the coordinates of the calibration field points determined by the adjustment of the geodetic network and the coordinates of the points determined from the point cloud were compared. Another part of the work deals with testing of the accuracy, when target's position is in different height levels.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.